logo
Telefono:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

Gruppo di servizio dell'attrezzatura medica da tecnologia del mondo della Cina

Vantaggioso per entrambe le parti insieme!

Casa ProdottiParti del monitor paziente

Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment

Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment

  • Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment
  • Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment
  • Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment
  • Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment
  • Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment
  • Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment
Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment
Dettagli:
Marca: Edan
Numero di modello: F300
Termini di pagamento e spedizione:
Quantità di ordine minimo: 1
Tempi di consegna: 3-5 giorni lavorativi
Termini di pagamento: T/T, Western Union, Paypal
Contatto
Descrizione di prodotto dettagliata
Numero di parte: E204460 Dispositivo compatibile: F300
Tipo di uscita: Quadratura (fase A/B) digitale Tensione operativa: 5 V CC
Vita rotazionale: ≥ 1,000,000 cicli Connessione: Connettore con intestazione pin con chiave
Vantaggi: Monitoraggio della protezione Garanzia: 90 giorni
Materiale: Miscela ABS/PC testurizzata Temperatura operativa: 0°C ~ 40°C

Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment

 

Encoder Introduction

 

The encoder features a compact, precision-designed housing made of high-strength engineering plastic with a smooth, matte finish that seamlessly integrates with the display's front panel. At its core, the encoder utilizes optical or mechanical sensing technology to convert rotational motion into precise digital signals for parameter adjustment and menu navigation. A white interface on the top allows for precise docking with the device's mainboard. Internally, it contains high-resolution encoding elements that generate quadrature output signals, enabling the display mainboard to accurately detect the direction and amplitude of rotation. The encoder features integrated button functionality for both selection and confirmation. It uses a pin header with anti-misalignment features to prevent incorrect installation. This encoder assembly serves as the primary user interface for adjusting critical parameters such as alarm limits, volume control, and menu navigation during fetal monitoring.

 

Edan F300 Fetal Patient Monitor Encoder E204460 For Replacement Medical Equipment 0

 

About Encoder

 

  • Precise Parameter Adjustment: Through rotation, it precisely controls the threshold adjustment of monitoring parameters such as fetal heart rate and uterine contractions, and switches menu options. Each rotation outputs a stable digital signal, ensuring adjustment accuracy.
  • Menu Navigation and Confirmation: Combined with the press function, it enables confirmation and return operations for menu options, simplifying the operation process for medical staff.
  • Stable Signal Transmission: It converts rotation and press actions into electrical signals and transmits them to the mainboard in real time, ensuring sensitive and delay-free device response.
  • Operation Feedback: Through an internal damping structure, it provides clear tactile feedback for rotation and press, allowing medical staff to intuitively perceive whether the operation is effective and avoid misoperation.

 

Troubleshooting

 

 

Cause

 

 

Troubleshooting and Solutions

1. Damaged internal encoder module

2. Poor contact or broken ribbon cable

3. Motherboard interface failure

 

1. Re-plug the ribbon cable and check if it is firmly plugged in.

2. Replace with a new encoder and test.

3. Check the motherboard connector for bent pins.

 

 

1. Encoder push switch damaged

2. Push mechanism stuck

3. Mainboard button detection circuit malfunction

 

1. Replace with a new encoder

2. Check for foreign objects obstructing the shaft

3. Troubleshoot the mainboard button detection circuit

 

Precautions

 

1. Anti-static: Wear anti-static gloves throughout operation to prevent static electricity from damaging the encoder or motherboard.

 

2. Handle with care: The encoder is a precision electronic component; avoid dropping, squeezing, or handling with excessive force.

 

3. Genuine parts: Always use genuine Mindray encoders (model E204460) to avoid compatibility issues.

 

4. Regular maintenance: Check the encoder's feel and response every 6-12 months and replace worn parts promptly.

Dettagli di contatto
China World Technology Medical Equipment Service Group

Persona di contatto: Rita

Telefono: +8618279091952

Invia la tua richiesta direttamente a noi
China World Technology Medical Equipment Service Group
Distretto di TianHe, Canton, Guangdong
Telefono:86-198-5481-5217
Sito mobile politica sulla riservatezza | La CINA buon qualità Monitor paziente usato fornitore. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.