logo
Telefono:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

Gruppo di servizio dell'attrezzatura medica da tecnologia del mondo della Cina

Vantaggioso per entrambe le parti insieme!

Casa ProdottiParti del monitor paziente

Welch Allyn Vital Signs Patient Monitor Parts 300 Series 53NTP SPO2 Assembly A010-0232-01 REV LOT90148

Welch Allyn Vital Signs Patient Monitor Parts 300 Series 53NTP SPO2 Assembly A010-0232-01 REV LOT90148

  • Welch Allyn Vital Signs Patient Monitor Parts 300 Series 53NTP SPO2 Assembly A010-0232-01 REV LOT90148
  • Welch Allyn Vital Signs Patient Monitor Parts 300 Series 53NTP SPO2 Assembly A010-0232-01 REV LOT90148
  • Welch Allyn Vital Signs Patient Monitor Parts 300 Series 53NTP SPO2 Assembly A010-0232-01 REV LOT90148
  • Welch Allyn Vital Signs Patient Monitor Parts 300 Series 53NTP SPO2 Assembly A010-0232-01 REV LOT90148
Welch Allyn Vital Signs Patient Monitor Parts 300 Series 53NTP SPO2 Assembly A010-0232-01 REV LOT90148
Dettagli:
Marca: Welch Allyn
Numero di modello: 300 serie 53NTP
Termini di pagamento e spedizione:
Quantità di ordine minimo: 1
Tempi di consegna: 3-5 giorni lavorativi
Termini di pagamento: T/T, Western Union, Paypal
Contatto
Descrizione di prodotto dettagliata
Nome di prodotto: Welch Allyn Vital Signs Monitor 300 serie 53NTP PN: A010-0232-01 GIRO LOT90148 AMTECH
Applicazione: attrezzatura medica, ICU, dispositivo dell'ospedale Garanzia: 90days
Colore: Bianco Temperatura di funzionamento: °F del °C +10 - +40 del °C +50 a °F +104
Altitudine di funzionamento: -170 m. - +4877 m. -557 ft + a 16.000 ft Shipping altitude: -615 m to 12,300 m -2000 ft to 40,000 ft
Temperatura di stoccaggio: -20 °C - un °F di +50 °C -4 a °F +122 Umidità relativa: 15% a 90% (senza condensazione)
Evidenziare:

REV LOT90148 Patient Monitor Parts

,

A010-0232-01 Patient Monitor Parts

 

Welch Allyn Vital Signs Monitor 300 Series 53NTP SPO2 Assembly A010-0232-01 REV LOT90148 AMTECH

 

 

► Brief Introduction

If the SpO2 sensor is connected to the patient during the measurement period, the pulse amplitude indicator rises and falls in rhythm with the monitored heart rate. The higher the display rises, the stronger the measured pulse; however, the height of the indicator display is not mathematically proportional to the volume of the pulse.During prolonged, continuous SpO2 monitoring, check the sensor site often, in compliance with the sensor manufacturer’s directions. Inspect the patient’s skin integrity and circulation, and relocate the sensor if necessary. Tissue damage can result from improper or prolonged sensor attachment.

 

 

► Specification

Operating Temperature +10 °C to +40 °C
+50 °F to +104 °F
Storage temperature -20 °C to +50 °C
-4 °F to +122 °F
Shipping altitude -615 m to 12,300 m
-2000 ft to 40,000 ft
Operating altitude -170 m to +4877 m
-557 ft to + 16,000 ft
Relative humidity 15% to 90% (non-condensing)

 

 

► Connecting and Disconnecting the SpO2 Sensor Cable

To connect the SpO2 sensor cable:

  1. Locate the SpO2 sensor cable connector (labeled SpO2) on the side of the monitor.
  2. Note the hole patterns of the connector halves, and align the cable connector accordingly.
  3. Carefully insert the SpO2 cable connector into the SpO2 monitor connector.

Welch Allyn Vital Signs Patient Monitor Parts 300 Series 53NTP SPO2 Assembly A010-0232-01 REV LOT90148 0

Verify that the sensor cable connector has slots on both sides. If the cable connector has a slot on only one side, then the sensor is not compatible with the monitor.

The SpO2 connectors are notched and flagged to ensure proper fit. If the connectors do not join easily, stop and verify the following:

• You have the correct SpO2 sensor.

• The cable connector is aligned correctly

 

If you are using a sensor extension cable, plug the sensor into the extension cable and plug the extension cable into the monitor.

 

 

► Disassembly

1. Remove the SpO2 assembly from the rear chassis and disassemble it as follows:

 

a. Remove the four screws (located on the inside of the rear chassis on the right side) securing the SpO2 assembly to the rear chassis

Welch Allyn Vital Signs Patient Monitor Parts 300 Series 53NTP SPO2 Assembly A010-0232-01 REV LOT90148 1

b. Remove the side panel and board assembly form the rear chassis

Welch Allyn Vital Signs Patient Monitor Parts 300 Series 53NTP SPO2 Assembly A010-0232-01 REV LOT90148 2

2. Remove the SpO2 board.
Remove the two screws securing the board to the side panel

Welch Allyn Vital Signs Patient Monitor Parts 300 Series 53NTP SPO2 Assembly A010-0232-01 REV LOT90148 3

 

 

► Shopping Information

Dear customers, To make sure the deal runs successfully and efficiently, please learn about and agree to the following clauses and terms. There are mainly two important things that you need to know well. The first thing is that you’d better bear in mind to look through all the product pictures with patience when purchasing so that you can confirm the item you are viewing is just what you are looking for and need to buy. It is absolutely necessary to do so as product pictures also play essential roles in product description, which helps you understand the product more intuitively and detailedly. The second thing comes to the customs fees. Please kindly know that the buyer is responsible for the customs fees such as all taxes and duties. Consequently, before paying for orders you must check out that the equipment your are ordering is allowed to imported into your country. That is to say, remember to read all the relevant information before ordering.

 

 

 

Thank you for your time! If you are interested in Welch Allyn Vital Signs Monitor 300 Series 53NTP SPO2 Assembly A010-0232-01 REV LOT90148 AMTECH, please let us know. Welcome to place your orders.

Thank you for your time and interest.

 

Dettagli di contatto
China World Technology Medical Equipment Service Group

Persona di contatto: Bella

Telefono: 86-18879075074

Invia la tua richiesta direttamente a noi
China World Technology Medical Equipment Service Group
Distretto di TianHe, Canton, Guangdong
Telefono:86-198-5481-5217
Sito mobile politica sulla riservatezza | La CINA buon qualità Monitor paziente usato fornitore. © 2021 - 2026 China World Technology Medical Equipment Service Group. All Rights Reserved.